Normal Volume Control Decelerating Waveform Breath
Normal Volume Targeted Breath
Normal Passive Expiration
Normal Pressure Support Breath
Maneuvers (all)
Plateau pressure (Pplat) measurement
Serial Measurement of Pplat at different PEEP levels
Measurement of Static Compliance
Measurement of Inspiratory Resistance
Calculating Tau
Measurement of zero autoPEEP
Measurement of AutoPEEP >2 cmH2O
Features Concerning for the Presence of autoPEEP (>=1 of any of)
Unequal Areas of Flow-Time Curve
Persistent End Expiratory Flow
Ineffective Triggering - if submitting as feature of autoPEEP, please also submit screen showing measured autoPEEP
Expiratory Asynchronies (all)
Active expiration
AutoPEEP (as noted above) and Management
Trigger Asynchronies (all)
Autotrigger and Management
Ineffective Trigger and Management
Reverse Trigger and Management
Double Trigger and Management
Due Apr 17
Flow Asynchronies (all)
Flow Starvation on Pressure Control and Management
Flow Starvation on Volume Control Decelerating Waveform and Management
Flow Starvation on Volume Targeted and Management
Cycle Asynchronies (all)
Premature Cycling on Pressure Control and Management
Premature Cycling on Volume Control and Management
Delayed Cycling on Pressure Control and Management
Delayed Cycling on Volume Control and Management
Other Cases and Maneuvers (>=2 of)
Breath Termination on Pressure Support Ventilation (PSV) - Expiratory Sensitivity (ESENS) adjustment for patient on PSV
* <todo>Recruitment-Inflation Ratio Measurement
* <todo>Increased Pressure-Time Product